Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd.
Main products:Process Calibrator,Clamp Meter,Digital Multimeter,Earth Ground Tester,Infrared Thermometer
Products
Contact Us
  • Contact Person : Ms. Chow Tracy
  • Company Name : Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd.
  • Tel : 86-755-26509606-809
  • Fax : 86-755-26502620
  • Address : Guangdong,Shenzhen,Room No.216,Third Floor,Jin Huiqiu Building,Langshan No.2Road,NorthArea,Science&TechnologyPark,Nanshan District,Shenzhen,China
  • Country/Region : China
  • Zip : 518057

FLUKE 1508 F1508 1KV Megger Insulation Resistance Tester F-1508

FLUKE 1508 F1508 1KV Megger Insulation Resistance Tester F-1508
Product Detailed
FLUKE 1508 Digital Insulation Resistance Tester 1000v Insulation Tester 0.01-10G ohms Insulation Resistance Test 20k ohms Tes FLUKE 1508 F1508 1KV Megger Insulation Resistance Tester F-1508 Insulation test of 0.01 M to 10 G ohmsInsulation test voltage: 50 V, 100 V, 250 V, 500 V and 1000 V, suitable for a variety of applicationsPass / fail (relatively) function, make the repeatability of the test is simple, convenientSave / calling function, a 19 storage unit, save time and manpowerRemote test probe, the repeatability of the test or difficult to reach by the measuring point test more convenientCircuit detection function, if the detected voltage greater than 30 V, is prohibited from testing, improve the protection ability of the staffCapacitive voltage automatic discharge function, improve the protection ability of the staffAC / DC voltage: 0.1 V to 600 V200 mA continuity measurementResistance: 0.01 to 20 K ohmsAutomatic shutdown function, to save battery powerCAT IV 600 V measurement level of security, improve the protection ability of the staffIncluding accessories: remote probe, test line and probe, the crocodile clipFluke MH10 magnetic suspension system can use the optional, hands free for other jobs4 AA alkaline batteries (NEDA 15 A or IEC LR6), at least 1000 insulation test1 years warranty

  AC / DC voltage measurementPrecisionThe range of 600 VResolution 0.1 V50 Hz to 400 Hz ± (% reading + Digital) ± (2% + 3)Input impedance3 M Ω (nominal), < 100 pFCommon mode rejection ratio (1 K Ω unbalanced):> 60 dB, DC, in 50 or 60 HzOverload protection600 V RMS or DCMeasurement of grounding resistanceScale / resolution:20 - 0.01.200 - 0.1.2000 - 1.20 K - 0.01 K.Precision+ (1.5% + 3)Overload protection2 V RMS or DCOpen-circuit voltage test:< > 4 V, 8 VShort circuit current:> 200 mAInsulation technology indexMeasuring range:0.01 M to 10 G.The test voltage50 V, 100 V, 250 V, 500 V, 1000 VThe test voltage accuracy:20% 0%Current short circuit test:1 mA, nominal valueAutomatic discharge:When C = 1 μ F or more hours, <0.5 discharge time of SCircuit detection function:Before testing the initialization, voltage if detected more than 30 V, is prohibited from test.The maximum capacitive load:Can work under the load of up to 1 μ F.General technical parametersApplied to a maximum voltage of any terminal:600 V AC RMS or DCStorage temperature:-40 ° C to 60 ° C (-40 ° F to 140 ° F)Working temperature-20 ° C to 55 ° C (-4 ° F to 131 ° F)Temperature coefficient:0.05 * (to the established accuracy) / ° C, 18 ° C temperature < or > 28 ° C (64 ° F < or > 82 ° F).Relative humidityFrom 0% to 95%, from 10 ° C to 30 ° C (50 ° F to 86 ° F).From 0% to 75%, from 30 ° C to 40 ° C (86 ° F to 104 ° F)From 0% to 40%, from 40 ° C to 55 ° C (104 ° F to 131 ° F)Vibration resistance:Randomly, 2 g, 5-500 Hz, with MIL-PRF-28800F, Class 2 instrument requirementsImpact resistance:1 meters drop, according to IEC 61010-1 version second (1 m drop test, 6, oak flooring) requirementsElectromagnetic compatibility:In the RF field of 3 V/M, accuracy of the (EN 61326-1:1997) =Safety:According to ANSI/ISA 82.02.01 (61010-1) requirements for CAT IV 600 V equipment, CAN/CSA-C22.2 No. 1010.1 and IEC/EN 2004 61010-1 Second EditionAuthentication.CSA, CSA/CAN C22.2 No. standard 1010.1; TUV, meet the standard IEC/EN 61010-1 Second EditionBattery:4 "AA" batteries ((NEDA 15A or IEC LR6)Battery life:For insulation test: a new battery at room temperature at least 1000 insulation test.Testing refers to standard test: 1000 V, to 1 M Ω, the duty cycle of 5 seconds to open, 25 seconds off.Resistance measurements: the new battery at room temperature at least 2500 grounding resistance measurement.Testing refers to standard test: 1 Ω, duty cycle of 5 seconds to open, closed 25 secondsSize:5 cm × 10 cm × 20.3 cm long width (1.97 in × 3.94 in wide x 8 in long)Weight550 g (1.2 lb)IP grade:IP40Altitude2000 m CAT IV 600 V, 3000 m CAT III 600 VNon work (storage): 12000 mOverload capacity:110% scope

Attn:Miss Tracy Chow

Skype:Tracy884404

Phone:0086-136-3169-7416

Email:tracy at yehai.net.cn

TM:chinayehai

QQ:862457367



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.