- Contact Person : Ms. Chow Tracy
- Company Name : Shenzhen Yehai Sci. & Tech. Deve. Co., Ltd.
- Tel : 86-755-26509606-809
- Fax : 86-755-26502620
- Address : Guangdong,Shenzhen,Room No.216,Third Floor,Jin Huiqiu Building,Langshan No.2Road,NorthArea,Science&TechnologyPark,Nanshan District,Shenzhen,China
- Country/Region : China
- Zip : 518057
Related Product Searches:FLUKE 1508 F1508 1KV Megger Insulation Resistance Tester F-1508,High Quality Insulation Resistance Tester ,Insulation Resistance Tester FLUKE 1508
AC / DC voltage measurementPrecisionThe range of 600 VResolution 0.1 V50 Hz to 400 Hz ± (% reading + Digital) ± (2% + 3)Input impedance3 M Ω (nominal), < 100 pFCommon mode rejection ratio (1 K Ω unbalanced):> 60 dB, DC, in 50 or 60 HzOverload protection600 V RMS or DCMeasurement of grounding resistanceScale / resolution:20 - 0.01.200 - 0.1.2000 - 1.20 K - 0.01 K.Precision+ (1.5% + 3)Overload protection2 V RMS or DCOpen-circuit voltage test:< > 4 V, 8 VShort circuit current:> 200 mAInsulation technology indexMeasuring range:0.01 M to 10 G.The test voltage50 V, 100 V, 250 V, 500 V, 1000 VThe test voltage accuracy:20% 0%Current short circuit test:1 mA, nominal valueAutomatic discharge:When C = 1 μ F or more hours, <0.5 discharge time of SCircuit detection function:Before testing the initialization, voltage if detected more than 30 V, is prohibited from test.The maximum capacitive load:Can work under the load of up to 1 μ F.General technical parametersApplied to a maximum voltage of any terminal:600 V AC RMS or DCStorage temperature:-40 ° C to 60 ° C (-40 ° F to 140 ° F)Working temperature-20 ° C to 55 ° C (-4 ° F to 131 ° F)Temperature coefficient:0.05 * (to the established accuracy) / ° C, 18 ° C temperature < or > 28 ° C (64 ° F < or > 82 ° F).Relative humidityFrom 0% to 95%, from 10 ° C to 30 ° C (50 ° F to 86 ° F).From 0% to 75%, from 30 ° C to 40 ° C (86 ° F to 104 ° F)From 0% to 40%, from 40 ° C to 55 ° C (104 ° F to 131 ° F)Vibration resistance:Randomly, 2 g, 5-500 Hz, with MIL-PRF-28800F, Class 2 instrument requirementsImpact resistance:1 meters drop, according to IEC 61010-1 version second (1 m drop test, 6, oak flooring) requirementsElectromagnetic compatibility:In the RF field of 3 V/M, accuracy of the (EN 61326-1:1997) =Safety:According to ANSI/ISA 82.02.01 (61010-1) requirements for CAT IV 600 V equipment, CAN/CSA-C22.2 No. 1010.1 and IEC/EN 2004 61010-1 Second EditionAuthentication.CSA, CSA/CAN C22.2 No. standard 1010.1; TUV, meet the standard IEC/EN 61010-1 Second EditionBattery:4 "AA" batteries ((NEDA 15A or IEC LR6)Battery life:For insulation test: a new battery at room temperature at least 1000 insulation test.Testing refers to standard test: 1000 V, to 1 M Ω, the duty cycle of 5 seconds to open, 25 seconds off.Resistance measurements: the new battery at room temperature at least 2500 grounding resistance measurement.Testing refers to standard test: 1 Ω, duty cycle of 5 seconds to open, closed 25 secondsSize:5 cm × 10 cm × 20.3 cm long width (1.97 in × 3.94 in wide x 8 in long)Weight550 g (1.2 lb)IP grade:IP40Altitude2000 m CAT IV 600 V, 3000 m CAT III 600 VNon work (storage): 12000 mOverload capacity:110% scope
Attn:Miss Tracy Chow
Skype:Tracy884404
Phone:0086-136-3169-7416
Email:tracy at yehai.net.cn
TM:chinayehai
QQ:862457367